Besides testing of complete products, Re/genT has also facilities available to test the performance of components. Components can be part of products with a cooling system, but are certainly not limited to this only.
Re/genT has facilities to automatically measure the energy consumption, cooling capacity, motor winding temperature and inverter efficiency of hermetic cooling compressors in cooling capacity ranges of 20W and higher according to ISO 917 and EN 13771.
Heat transfer measurements of air or liquid evaporators and condensers (e.g. Roll bond, Fin and tube, Reyert, water cooled condensers) can be executed on dedicated test rigs. Examples of test standards applied are EN 1117 and EN 1118.
Other examples of tested components are suction tube heat exchangers, expansion devices, liquid pumps and fans.